SIR 90 day Monitoring of Desiccators |
|
Project Goal
The goal of this project was to assess the SIR resistance of storage conditions.
Background / History / Assembly Material
Two sets of desiccant conditions were to be stored at room temperature in a high humidity area (75% RH as a room with and inline cleaner) and resistance measurements were taken daily on PCB electrodes internal to the sealed enclosure.